Bench Top Manual Presses
| iSAF – Designed for an array of different applications and processes for example; pelletizing, destructive testing, rosin and other fluid extraction, pressure forming, etc.
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Eppendorf Centrifuge 5804
| iSAF – Max. capacity: 4 × 250 mL/2 × 5 MTP, Swing-bucket rotors and adapters accommodate tubes and bottles from 0.2 mL to 250 mL. Plate rotor for centrifugation of all types of MTP, PCR, cell culture, or Deepwell Plates
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Spectrometer + ICCD
| iSAF – o Wavelength range: 300 – 800 nm o Andor iStar ICCD o Gate time: 4 ns
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Laser-induced fluorescence
| iSAF – Nd:YAG + dye laser o Wavelength range: 200 – 600 nm. Rep rate: 20 Hz o Pulse duration: 6-10 ns
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
High-speed imaging
| iSAF – Four mid-IR units (4 – 6 μm) o H2O, CO2, NO, CH2O detections, < 50 mW power, < 10,000 Hz scan rate
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Tunable diode lasers/detectors
| iSAF – Four mid-IR units (4 – 6 μm). H2O, CO2, NO, CH2O detections, < 50 mW power, < 10,000 Hz scan rate
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Hyperspectral Infrared Imaging
| iSAF – Currently being upgraded, Telops Hyper-Cam MWE FAST, Spectral range: 1.5 – 5.4 μm, Spectral resolution: 0.25 – 150 cm-1, Spatial resolution: 320 x 256 pixels, Frame rate: 0.032 – 32 cubes/s, Exposure time: 1 μ…
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
High-speed IR imaging
| iSAF – Telops FAST M3k o Spectral range: 1.5 – 5.4 μm. Resolution: 320 x 256 pixels. Frame rate: 3,100 fps (full res) – 100,000 fps (64 x 4 pixels). Exposure time: 1 μs – full frame
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
EQX-850 LDLS – High Brightness, Laser-Driven Light Source
| iSAF – Wavelength Range: 170 nm – 2500 nm Plasma Size (FWHM): With Retro: 140 μm X 290 μm Dual Output: 120 μm X 280 μm Numerical Aperture: 0.58 NA Bulb Lifetime: 10,000 hours Distance of Plasma from Output Window 13.7 mm La…
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
LCA
| iSAF equipment
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Predictive chemical kinetic model development
| iSAF equipment
| Computational
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Model refinement using quantum chemical computations
| iSAF equipment
| Computational
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Chemical kinetic Model generation using the Reaction Mechanism Generator software
| iSAF equipment
| Computational
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Lab scale continuous (membrane) reactor system
| iSAF – For high temperature and pressure reactions (up to 500 C, 40 bar) with on line MS
| Reactors
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Combustion test facility for SAF testing
| iSAF equipment
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
High-pressure/high-temperature reactor
| iSAF equipment
| Reactors
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
UYA 2.4Y.F Ultra-Microbalance
| iSAF – ultra-microbalance is an optimized modern device which features an option of automatic level control (Level SENSING) as one of numerous functions. The practical effect of balance customization are individual user profil…
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Greenlight G20 fuel cell testing station
| iSAF – Available with Greenlight's integrated 'Intelligent Fuel Cell Diagnostics' capabilities: FCDX, G20 power range: up to 100 Watts, Manual and automated operation, Emerald control software, Automated scripting capab…
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
Y&D7300N bench -top robot
| iSAF – This product has a wide range of applications, such as watch, relay packaging, mobile phone key dispensing, mobile phone battery packaging, notebook battery packaging, coil dispensing, PCB binding sealing, IC sealing, h…
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
875 Redox Flow Cell Test System
| iSAF – 0.07 A, .07 A, 7 A, 20 A current range, High-current, multi-range potentiostat operates in current - or voltage -controlled operation, ± 5 V operation for non -aqueous electrolytes, Charge/discharge cycling & per…
| Analyzers
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
WaveDriver 40 DC Bipotentiostat
| iSAF – This WaveDriver® series bipotentiostat/galvanostat is an affordable dual-electrode electrochemical workstation. The WaveDriver 40 is a true integrated bipotentiostat, capable of controlling one or two working electrodes…
| Analyzers, Heaters
| iSAF - The Israeli Sustainable Aviation Fuel
| Keren-Or Rosner |
|  |
|
GC-MS
| | Chromatography Mass Spectrometry
| Chemical and Surface Analysis Lab
| Larisa Panz |
|  |
|
MALDI
| | Masspectrometry
| Chemical and Surface Analysis Lab
| Larisa Panz |
|  |
|
Q-TOF LCMS Bruker
| ESI APCI Solid prob APPI
| Chromatography, Mass Spectrometry
| Chemical and Surface Analysis Lab
| Larisa Panz |
|  |
|
Q-TOF LCMS Waters
| ESI
| Chromatography, Mass Spectrometry
| Chemical and Surface Analysis Lab
| Larisa Panz |
|  |
|
Dual beam Ga+ Helios G3 FIB+SEM
| Ga+ FIB, HRSEM, EDS, EBSD. Material cross- srectioning, TEM lamella preparation, failure analysis, nano-patterning, high resolution imaging.
| HRSEM and (Ga+) FIB
| RBNI FIB Lab
| Larisa Popilevsky |
|  | |
Clean room
| Clean room 100,000
| Equipment Assembly
| Asher Space Research Institute
| Lee Nudel |
|  |
|
GPS simulators
| Simulating GPS RF Signals
| Engineering
| Asher Space Research Institute
| Lee Nudel |
|  |
|
Satelite Ground Station
| S-band, VHF/UHF antennas
| Space
| Asher Space Research Institute
| Lee Nudel |
|  |
|
Thermal Cycling Oven
| 150C to -80C
| Equipment testing
| Asher Space Research Institute
| Lee Nudel |
|  |
|
Vaccum Chambers
| | Space Qualifications
| Asher Space Research Institute
| Lee Nudel |
|  |
|
3D Metal printing EOS M290
| High-temperature capability, 250 X 250 X 325 mm, metal alloy support.
| Selective laser melting (SLM)
| IMT- Israel Institute of Materials Manufacturing Technologies
| Leonid Chernobylskiy |
|  |
|
ATOmizer
| Metal atomization (powders production), flexible material processing
| Atomization
| IMT- Israel Institute of Materials Manufacturing Technologies
| Leonid Chernobylskiy |
|  |
|
JGMaker
| Dual independent extruders, different filaments (PLA, Pet-g, ABS)
| Fused deposition modelling (FDM)
| IMT- Israel Institute of Materials Manufacturing Technologies
| Leonid Chernobylskiy |
|  |
|
Particle Size and Shape Analyzer Camsizer
| Powder size measurements, range from 0.8 mm to 8 mm.
| Optical system with high resolution
| IMT- Israel Institute of Materials Manufacturing Technologies
| Leonid Chernobylskiy |
|  |
|
Vacuum Furnace SecoWarwick
| Temperature range up to 1200 degrees , advanced cooling options.
| Heat treatment, Vacuum Furnace
| IMT- Israel Institute of Materials Manufacturing Technologies
| Leonid Chernobylskiy |
|  |
|
XRF Thermofisher
| Portable, accurate measurements of metal alloys and coatings
| X-ray fluorescence
| IMT- Israel Institute of Materials Manufacturing Technologies
| Leonid Chernobylskiy |
|  |
|
3D Metal printing Arcam A2X
| High-temperature capability, 200x200x380mm , metal alloy support.
| Electron Beam Melting (EBM)
| IMT- Israel Institute of Materials Manufacturing Technologies
| Leonid Chernobylskiy |
|  |
|
Chromium X (10x Genomics)
| Single cell RNA-seq, single cell TCR/BCR sequencing, multi omics
| Single Cell Technology
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
CosMx (Nanostring)
| Single-cell spatial transcriptomics
| Spatial transcriptomics based on in-situ
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
CytAssist (10x Genomics)
| Spatial transcriptomics
| Spatial transcriptomics based on NGS
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
Genetic Analyzer 3500XL
| Sanger seqeuncing, human cell line authentication
| Sanger and genotyping
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
MinION (Oxford Nanopore)
| Long-read DNA-seq
| Long read sequencing
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
NanoDrop 2000 (Thermo)
| DNA/RNA quantification
| Spectrophotometer
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
Nepa21 Super Electroporator
| Cell transfection
| Cell transfection
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
Nextseq 2000 (Illumina)
| RNA-seq, miRseq, whole genome- equencing (WGS), ChIP-seq, CEL-seq, Amplicon-seq, 16S, RRBS, Exome
| Next-generation sequencing (NGS)
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
Qiacube Connect (Qiagen)
| DNA/RNA extraction
| DNA/RNA Extraction
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
QIAcuity Digital PCR
| Digital real-time PCR
| Digital qPCR
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
QuantStudio1
| Real-time PCR
| Real-time PCR
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
QuantStudio3
| Real-time PCR
| Real-time PCR
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
Qubit
| DNA/RNA quantification
| Fluorimeter for DNA/RNA quantification
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
Tapestation 4200 and 2200 (Agilent)
| DNA/RNA quality
| DNA/RNA QC
| Azrieli-Technion Genomics Center
| Liat Linde |
|  |
|
EM AFS2
| Freeze Substitution and Low Temperature Embedding System
| Electron microscopy
| Biomedical Core Facility (BCF)
| Lihi Shaulov |
|  |
|
K850 Critical Point Dryer
| Critical Point Dryer
| Electron microscopy
| Biomedical Core Facility (BCF)
| Lihi Shaulov |
|  |
|
Q150T ES
| Combined system for sputter coating or carbon/metal evaporation
| Electron microscopy
| Biomedical Core Facility (BCF)
| Lihi Shaulov |
|  |
|
Sample Preparation for Biomedical electron microscopy services
| Sample preparation and acquisition for scanning and transmission electron microscopy
| Biological electron microscopy
| Biomedical Core Facility (BCF)
| Lihi Shaulov |
|  |
|
TEM - FEI Talos L120C
| Transmission electron microscope
| Electron microscopy
| Biomedical Core Facility (BCF)
| Lihi Shaulov |
|  |
|
Ultramicrotome Leica EM UC7
| Thin Sections at Room and Cryo Temperatures
| Electron microscopy
| Biomedical Core Facility (BCF)
| Lihi Shaulov |
|  |
|
Advanced Image Analysis Software
| FIJI, Image J, Cell Profiler, Illastic, Imaris, Stardist, QuPath, CellPose
| Software for Image Processing
| Life Sciences and Engineering Infrastructure Center (LSE)
| Lital Shani Zerbib |
|  |
|
SEM - FEI E-SEM Prisma
| EDS. WDS, Low-vacuum
| Scanning electron microscopy
| EMC - The Electron Microscopy Center
| Maria Koifman |
|  |
|
SEM - FEI E-SEM Quanta 200
| EDS. WDS
| Scanning electron microscopy
| EMC - The Electron Microscopy Center
| Maria Koifman |
|  |
|
Rigaku SmartLab 3kw
| Identification of molecules arrangement within the crystal structure.
| Microstructure Analyzer - X-ray diffractometer (XRD)
| The Russell Berrie Nanoparticles and Nanometric System Characterization Center
| Maya Davidovich-Pinhas |
|  |
|
Abbelight SAFe 360
| Lasers: 405, 488, 555, 640 Inverted microscope TIRF\Hilo\EPI illumination 2D and 3D SMLM super resolution with Astigmatsim lens
| Super resolution PALM dSTORM
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Alveole -Primo
| DMD, laser 375
| Micropatterning
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Axio Imager Z2 upright
| Upright microscope. Suited for fixed specimens. Motorized stage and X-cite metal halide light illumination, High resolution monochrome Zeiss Axiocam 807 camera , and Zeiss Axiocam 105 color camera for brightfield and polarized light.
| Fluorescence Microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Axio observer inverted
| Inverted microscope for transmitted and fluorescence widefield microscopy of fixed specimens and time lapse of live samples
| Fluorescence Microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Bruker AFM CellHesion 300
| SmartMapping,Force spectroscopy
| Atomic Force Microscopy
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Bruker Ultima 2-Photon Plus
| Tunable laser (680–1300 nm) and Fixed output: 1045 nm, 4 GaAsP PMT channels, Galvo and resonant scanners, ETL focus
| 2 Photon
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Confocal Zeiss LSM 700
| Lasers: 405, 488, 555, 633 nm Inverted microscope
| Confocal Microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Confocal Zeiss LSM 880
| Lasers: 405, 458, 488, 514, 561, 633 nm upright microscope Airyscan super resolution detector, Fast mode, GaAsP- spectral detector
| Confocal Microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Confocal Zeiss LSM 900 Inverted
| Lasers: 405 488 561 640 nm inverted microscope, Airyscan2 super resolution detector, MLPX 2 and 4; 2 GaAsP detectors
| Confocal Microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Confocal Zeiss LSM 900 Upright
| Lasers: 405 488 561 640 nm upright microscope, Airyscan2 super resolution detector, MLPX 2 and 4; 2 GaAsP detectors
| Confocal Microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Incucyte SX5
| High throughput, continuous live cell imager transmitted and fluorescence
| Live-Cell Analysis System
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Infinity Abberior STED Confocal microscop
| Stimulated Emission Depletion (STED) 3D STED and FLIM
| Super Resolution 3D STED
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Life Canvas Smart SPIM Lightsheet
| Lasers: 405, 488, 561, 642 nm. Objective lenses:x1.8 x3.6, x9 x15,
| Lightsheet microscope for imaging large cleared tissue samples
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Lunaphore Comet
| 40-plex imaging per slide,multiomics with RNAscope HiPlex
| Spatial Biology
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Olympus MVX10M
| Macro zoom microscope. Brightfield and fluorescent specimens
| Macro microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Slide Scanner Olympus Slideview VS200
| 150 slide capacity, brightfield, polarized light and fluorescence scanning
| Slide Scanner
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Spinning Disk Confocal Olympus IXplore-Spin
| Lasers: 405 488 561 640 nm, Prime BSI Express monochrome camera
| Confocal Microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Zeiss Celldiscoverer 7
| High content screening live cell inverted widefield imaging system
| Fluorescence Microscope
| Biomedical Core Facility (BCF)
| Maya Holdengreber |
|  |
|
Subsonic Wind Tunnel (14)
| Air speed range 10-90 m/sec, test section 100X100 cm, balance measurements
| Aerodynamic measurments
| Technion Wind tunnel Complex
| Michael Dunaevsky | |  |
|
Subsonic Wind Tunnel (15)
| Air speed range 0-50 m/sec, test section 50X50 cm, flow field measurements (PIV)
| Aerodynamic measurments
| Technion Wind tunnel Complex
| Michael Dunaevsky | |  |
|
Supersonic Tunnel
| Mach number 1.6-3.5, test section 40X50 cm, balance measurements, Schlieren
| Aerodynamic measurments
| Technion Wind tunnel Complex
| Michael Dunaevsky | |  |
|
Transonic Wind Tunnel
| Mach number 0.2-1.1, test section 80X60 cm, balance measurements, Schlieren
| Aerodynamic measurments
| Technion Wind tunnel Complex
| Michael Dunaevsky | |  |
|
Wind tunnel accessories
| Design and assembly of wind-tunnel balances for measuring forces and moments from a few grams and up to 250 kg kilograms
| Aerodynamic measurments
| Technion Wind tunnel Complex
| Michael Dunaevsky | |  |
|
Academic Tools and Tutorials
| | Library Services
| Technion libraries
| Moti Yeger | |  |
|
Advanced Research Assistance
| | Library Services
| Technion libraries
| Moti Yeger | |  |
|
BI reports
| Display publications in your personal website
| Library Services
| Technion libraries
| Moti Yeger | |  |
|
Biboxx
| | Library Services
| Technion libraries
| Moti Yeger | |  |
|
The Historical Archive
| X-ray diffraction of the organic compounds - Mo and Cu radiation sources
| Library Services
| Technion libraries
| Moti Yeger | |  |
|
Inductively Coupled Plasma (ICP)
| ICP-OES is an analytical technique that can be used to measure elements in a sample
| ICP-OES
| The Center for Research in Environmental Engineering
| Naama Manor Korin |
|  | |
Rigaku diffractometer
| Determination of the crystal structures of the small organic molecules
| X-ray lab
| Chemical and Surface Analysis Lab
| Natalia Fridman |
|  |
|
Rigaku XtaLAB Synergy-S
| The Cypher ES Environmental AFM provides an exceptional performance in resolution, speed and stability in standard contact and tapping modes. It is compatible with a complete range of modes and accessories. In addition, it enables studying samples in controlled gas or liquid environments, doing electrochemical experiments and measuring conductivity of samples.
| X-ray diffraction
| Chemical and Surface Analysis Lab
| Natalia Fridman |
|  |
|
Axio Imager Z1 upright microscope
| Fully motorized upright fluorescent microscope. Equipped with a camera.
Motorization includes: Z sectioning, objectives, filters, light and fluorescence intensities
| Fluorescence Microscope
| Life Sciences and Engineering Infrastructure Center (LSE)
| Nitsan Dahan |
|  |
|
Biotek Cytation 5
| Automated high content high throughput imaging, live imaging, up to 8 plates
| High Content Imaging
| Life Sciences and Engineering Infrastructure Center (LSE)
| Nitsan Dahan |
|  |
|
Confocal Zeiss LSM 700
| Inverted confocal, Lasers: 405, 488, 555, 639 nm
| Confocal Microscope
| Life Sciences and Engineering Infrastructure Center (LSE)
| Nitsan Dahan |
|  |
|
Confocal Zeiss LSM 710
| Inverted confocal, Lasers: 405, 454, 488, 514, 543, 639nm. GaAsP detectors. Full incubation for live imaging
| Confocal Microscope
| Life Sciences and Engineering Infrastructure Center (LSE)
| Nitsan Dahan |
|  |
|
Confocal Zeiss LSM 880 multi photon
| Lasers: 458, 477, 488, 514, 561, 633 nm and multi-photon tunable laser 690-1040 nm and Spectral imaging
| Confocal Microscope
| Life Sciences and Engineering Infrastructure Center (LSE)
| Nitsan Dahan |
|  |
|
Confocal Zeiss LSM 980 AiryScan
| Lasers: 405, 454, 488, 514, 543, 639nm. Spectral detector, AiryScan, uper-resolution. Full incubation for live imaging
| Confocal Microscope
| Life Sciences and Engineering Infrastructure Center (LSE)
| Nitsan Dahan |
|  |
|
Imaris - Image analysis software
| Image analysis software for analysis of 3D/4D/5D images
| Software for Image Processing
| Life Sciences and Engineering Infrastructure Center (LSE)
| Nitsan Dahan |
|  |
|